Sensus 243-8 regulator pdf

For additional information, please contact your sensus sales office or authorized distributor. If an outlet stop valve is used, it should be opened first. Sensus 243 gas pressure regulator series 2438 24312 24382hp. Catalog clearance center grainger choice hot buys knowhow rebates replacement parts supplylink todays features webinars services environmental, health and safety services facility services energy services lighting solutions grainger midstream utility rebate incentive emergency services grainger keepstock inventory management grainger. This large capacity device provides great field versatility for commercial and industrial applications. The model 14380 regulator can be used for the flowing temperature of 20f to 150f 28. Sensus large capacity industrial service regulators are designed and built for commercial, industrial, and gas distribution use. See bulletin td1l the maximum pressure to which the 14380 diaphragm case may. A special spring is available for the 24382 to relieve at. New linethe model 243 service regulator is a large. Make sure the regulator is entirely depressured before 243 8 diaphragm 1438215000 disassembling.

Model 14380 natural gas meter natural gas regulator. Natural gas regulators 243 commercial regulator sensus. Sensus natural gas products20 condensed catalog by. As a result of the collar connection between the fully interchangeable bodies and the diaphragm case, they have remarkable field versatility. For additional information, please contact your sensus sales. Regulator installation and maintenance instructions 243. We use these to track application performance, behavior and functionality. The model 243 regulator may be used for flowing gas temperatures from. Remove seal and wire if applicable from the regulator. Sensus 243 8 2 natural gas regulator, 112npt inlet pressure. Models 243 8 1m, 243 8 2m and 243 122m retrofit instructions 1. Sensus gas regulator20 condensed catalog by sensus issuu.

Check the oring for dirt or damage before installation. High pressure regulator pressure loaded regulator 24381 24382 24384 24386 2438hp 2438pl for additional information on irv refer to page 5. Accuracy is largely unaffected by changes in the inlet pressure. Model 243dot duplex overpressure tandem package monitor sets internal relief valve if an irv is used, it should only be used in the downstream monitor as shown in the model numbers table. Sensus series 243 gas regulator 112 npt with 12 10. The model 243 service regulator is a large capacity industrial service regulator designed for commercial, industrial, and gas. Unfollow sensus regulators to stop getting updates on your ebay feed. Sensusrockwellequimeter high pressure gas regulator part.

High pressure regulator pressure loaded regulator 243 8 1 243 8 2 243 8 4 243 8 6 243 8hp 243 8pl for additional information on irv refer to page 5. Model 243 service regulators construction and design features model 24381 model 243121 travel stop a travel stop is located in the 243121 and the 243124 to provide overpressurization protection. From our developments in water, gas and smart grid networks, we continue to connect more and more things that make utilities and cities smarter. They offer exceptionally precise regulation and are accurate to within 0. Looking for sensus gas pressure regulator, for use with mfr. The standard irv begins to relieve at approximately 9 w. Mark ii 4, 6, 8, and 12 inch 100, 150, 200 and 300 mm overview sensus mark ii turbometers provide greater range, compact size, and simplified maintenance when compared to. Run vent pipe from the regulator vent connection to a safe place outside. For lpco refer to page 6 the term standard refers to nonirv configurations. Description number 1 seal cap 1431600500 2 tetraseal seal cap, 214 x 238 905241. Pilotoperated regulators 243rpc gas regulator sensus.

Sensus regulator series 243 8 1, 243 8 2, 243 121, 243 122 these large capacity service regulators are designed and built for commercial, industrial, and gas distribution work. They are ideal for pressure factor measurement, pressure compensated metering, fixedfactor billing and more. They are right at home in such places as factories and foundries. Sensus metering systems produces a broad product line of. Sensus 143802hp natural gas regulator, 1npt, high pressure outlet inlet pressure. New relic cookies are necessary for the site to run because they report if everything is working as expected and log any errors if it isnt. Td1 model 14380 service regulator cici boiler rooms. Sensus model 243rpc regulators are based on our rugged model 243 regulator with a smaller, secondary control regulator that senses regulated pressure and then operates the main valve to control the overall flow of gas. Model 243 rpc regulator installation and maintenance instructions model 243 rpc regulator the 243 rpc is a genuine pilot operated regulator relay principle of operation at an economical price. Extend the value of your infrastructure with new applications. Page 1 model 496 domestic service regulator installation and maintenance instructions 1 spring cap 2 adjustment ferrule the model 496 is a general purpose gas pressure regulator for natural gas, air, co, propane, butane, 3 spring 11 vent nitrogen, and other gases. Model 243 service regulators marshall w nelson and.

Spring color 24312 2438 outlet pressure range spring part number redblack blueblack greenblack red blue green. Genuine, pilotoperated regulators use the same relay operation. Natural gas regulators with large capacity for big performance. Sensus 496 installation and maintenance instructions pdf. Vent piping for regulators with an internal relief valve models 243122 or 24382 must be large enough to vent all relief. Sensus 24382 line pressure regulator 114npt, 112npt, 2npt, or 2flgd. Its outstanding performance and versatility make it an excellent choice for use on industrial meter sets, combustion equipment, boilers, burners, unit heaters, furnaces, ovens and other. Vent piping should be as short and direct as possible. Carefully note location and position of all disassembled 1438201700 243 8 diaphragm pan parts to be certain reassembly is correct. Description number 1 seal cap 1431600500 2 tetraseal seal cap, 214 x 238 905241 3 adjustment spring button 1431600900. The sensus qrs is a mechanical damping device that enhances gas pressure regulator. Our average response time is within 1 hour during business hours. Regulators installed indoors must be vented outside. Use the adobe navigator buttons on the icon bar to page thro ugh the different catalog sections.

This document replaces td1 all products purchased and services performed are subject to sensus terms. Vent piping for regulators with internal relief valve models. Regulator installation and maintenance instructions 243 service regulators introduction the 243 is a large capacity generalpurpose gas pressure regulator. Ingreg43031a model 243 rpc regulator installation and maintenance instructions model 243 rpc regulator preliminary instructions the 243 rpc is a genuine pilot operated regulator relay principle of operation at an economical price. Model 043c service regulator sensus metering systems technical data spring ranges outlet pressure spring ranges color std 5 to 7 w. The relay principle means exceptionally precise pressure control. The model 243 service regulator is a large capacity industrial service regulator designed for. The allowable overpressurization is the lowest of the maximum pressures permitted by federal codes, state codes, equimeter bulletin rds1498, or other applicable standards. The allowable overpressurization is the lowest of the maximum pressures permitted by federal codes, state codes, sensus bulletin rds1498, or other applicable standards. Spring color 243 12 243 8 outlet pressure range spring part number redblack blueblack greenblack red blue green.

352 1090 886 1210 1418 1000 1297 469 449 1165 1104 1183 1213 78 119 1382 458 511 852 1113 278 947 1485 964 847 1061 732 1175 52 131 692 1601 350 1380 785 1 652 1224 11 1158 1106 77